Error codes
Status | Color | Timing | Count | Description |
---|---|---|---|---|
Operational | Green | Continuously on | / | Normal operation |
Powersave | Green | Heartbeat | / | Powersave |
Note: After 1 minute, the Multi Swing 2G will go into powersave mode to draw less current from the battery. However, when an error occurs in the powersave mode, you will not see this via the LEDs. You will just notice that you cannot operate the arm anymore.
|
||||
Warning | Orange | Flash | See Installation manual | Part of the functionality is disabled |
Error | Red | Flash | See Installation manual | Something went wrong |
Warnings
The Multi Swing 2G will block certain functionality, in order to guarantee a safe operation of the device. The warning will be logged into the memory of the Multi Swing 2G. Connect the device to the mo-vis Configurator Software to read out the status. You can find more information on how to do that in the Configurator Software User manual.
The LED light will flash orange and the number of flashes indicates the warning. Depending on your settings, you will receive auditive feedback as well (see Auditive feedback).
Flash count | Reason | Required action |
---|---|---|
2 | All motor actions are blocked because motor current is too high OR because the arm cannot rotate |
|
3 |
Note: This warning can only occur when a switch of the input tip or ring is configured as safety switch. See Input settings for more information.
All actions from the defective safety switch are blocked |
|
4 | All motor actions are blocked, because the battery voltage supply is either lower than 14V or higher than 34V |
|
Errors
The Multi Swing 2G will be blocked completely. The error will be logged into the memory of the Multi Swing 2G. Connect the device to the mo-vis Configurator Software to read out the status. You can find more information on how to do that in the Configurator Software User manual.
The LED light will flash red and the number of flashes indicates the error. Depending on your settings, you will receive auditive feedback as well (see Auditive feedback).
Flash count | Reason | Required action |
---|---|---|
5 | ECODE_HALL_SENSOR_I2C_TIMEOUT | Contact mo-vis |
5 | ECODE_HALL_SENSOR_I2C_ERROR | |
5 | ECODE_HALL_SENSOR_WRONG_DEVICE | |
5 | ECODE_HALL_SENSOR_MISALIGNED | |
5 | ECODE_TASK_HALL | |
6 | ECODE_MOTOR_DRIVER_FAULT | |
6 | ECODE_MOTOR_DRIVER_FAULT_CURRENT | |
6 | ECODE_MOTOR_CURRENT_TOO_LOW | |
7 | ECODE_VREF | |
7 | ECODE_BIDIR_SW_SHORT | |
7 | ECODE_BIDIR_SW_OPEN | |
7 | ECODE_TASK_ADC | |
8 | ECODE_DOUBLE_WARN |
|
9 | ECODE_TEST_FLAGS | Contact mo-vis |
10 | ECODE_PREPARATION_FAILED | |
10 | ECODE_OPERATIONAL_FAILED | |
10 | ECODE_POWERSAVE_FAILED |