R-net trip codes
Trouble:
When a fault is detected by the device, an R-net trip code will be generated. The trip code will be shown on the joystick (if it is present and equipped with a graphic display). The trip code will also be logged in the R-net system and can be investigated using the R-net PC Programmer.
If you want to learn more about trip codes, see the Curtiss-Wright manual | SK77981-14 R-net Technical Manual.
R-net trip code | Reason | Required action |
---|---|---|
9600 | Uart overflow | Update firmware or replace PCB. |
9601 | Uart underflow | |
9602 | Packet transmission exceeded maximum number of retries | Update firmware or replace PCB. |
9603 | TX handle overflow | |
9604 | RX handle overflow | Update firmware or replace PCB. |
9605 | Invalid sequence number | |
9606 | Ack number does not match | Update firmware or replace PCB. |
9607 | Invalid packet descriptor | |
9608 | Incorrect R-net version | Update firmware or replace PCB. |
9609 | Chip tripped | |
960A | Invalid response when accessing a file | Update firmware or replace PCB. |
9620 | CPU error | |
9621 | Code error | Update firmware or replace PCB. |
9640 | One or more test flags not set | Redo tests and/or replace PCB. |
9641 | Software watchdog | Update firmware or replace PCB. |
9642 | There was a problem during the preparation of the R-net system | Check R-net fault on joystick display or in the R-net PC programmer. Check R-net configuration. |
9643 | Left sensor is faulty | Replace sensor board and calibrate. |
9644 | Right sensor is faulty | |
9645 | Left throttle is faulty | Replace throttle and calibrate. |
9646 | Right throttle if faulty | |
9647 | There is an R-net trip code | Check R-net fault on joystick display or in the R-net PC programmer. |
9648 | Factory test failed | A fault occurred during factory testing. |
9649 | Field test failed (calibration) | A fault occurred during field testing (calibration). |
9800 | API_MSG_SEND_TO_FREQUENTLY | Update firmware or replace PCB, check R-net configuration. |
9801 | API_MSG_DATA_OUT_OF_RANGE | |
9802 | API_MSG_ID_UNKNOWN | Update firmware or replace PCB, check R-net configuration. |
9803 | API_MSG_DATA_INCORRECT_AMOUNT | |
9804 | API_MSG_TOO_SHORT | Update firmware or replace PCB, check R-net configuration. |
9805 | API_MSG_TOO_LONG | |
9806 | API_MSG_NOT_ENABLED | Update firmware or replace PCB, check R-net configuration. |
9807 | API_RESPONDED_OUT_OF_TIME | |
9808 | API_MSG_REQUIEREMENT_WRONG | Update firmware or replace PCB, check R-net configuration. |
9809 | API_MSG_INVALID_IN_CURRENT_STATE | |
9810 | DATA_PACKET_WITH_INVALID_SEQ_NR | Update firmware or replace PCB, check R-net configuration. |
9811 | ACK_PACKET_WITH_INVALID_SEQ_NR | |
9812 | INVALID_HEADER | Update firmware or replace PCB, check R-net configuration. |
9813 | PACKET_TIMEOUT | |
9814 | CHIP_INT_ERR0 | Update firmware or replace PCB, check R-net configuration. |
9815 | CHIP_INT_ERR1 | |
9816 | HOST_RESTART_AFTER_CORRECT_INIT | Update firmware or replace PCB, check R-net configuration. |
9817 | HOST_INCOMPATIBLE_SERIAL_PROTOCOL_VERSION | |
9820 | CHIPSET_INTERNAL_QUEUE_OVERFLOW | Update firmware or replace PCB, check R-net configuration. |
9821 | CHIPSET_HEARTBEAT |