R-net trip codes

Trouble:

When a fault is detected by the device, an R-net trip code will be generated. The trip code will be shown on the joystick (if it is present and equipped with a graphic display). The trip code will also be logged in the R-net system and can be investigated using the R-net PC Programmer.

If you want to learn more about trip codes, see the Curtiss-Wright manual | SK77981-14 R-net Technical Manual.

R-net trip code Reason Required action
9600 Uart overflow Update firmware or replace PCB.
9601 Uart underflow
9602 Packet transmission exceeded maximum number of retries Update firmware or replace PCB.
9603 TX handle overflow
9604 RX handle overflow Update firmware or replace PCB.
9605 Invalid sequence number
9606 Ack number does not match Update firmware or replace PCB.
9607 Invalid packet descriptor
9608 Incorrect R-net version Update firmware or replace PCB.
9609 Chip tripped
960A Invalid response when accessing a file Update firmware or replace PCB.
9620 CPU error
9621 Code error Update firmware or replace PCB.
9640 One or more test flags not set Redo tests and/or replace PCB.
9641 Software watchdog Update firmware or replace PCB.
9642 There was a problem during the preparation of the R-net system Check R-net fault on joystick display or in the R-net PC programmer. Check R-net configuration.
9643 Left sensor is faulty Replace sensor board and calibrate.
9644 Right sensor is faulty
9645 Left throttle is faulty Replace throttle and calibrate.
9646 Right throttle if faulty
9647 There is an R-net trip code Check R-net fault on joystick display or in the R-net PC programmer.
9648 Factory test failed A fault occurred during factory testing.
9649 Field test failed (calibration) A fault occurred during field testing (calibration).
9800 API_MSG_SEND_TO_FREQUENTLY Update firmware or replace PCB, check R-net configuration.
9801 API_MSG_DATA_OUT_OF_RANGE
9802 API_MSG_ID_UNKNOWN Update firmware or replace PCB, check R-net configuration.
9803 API_MSG_DATA_INCORRECT_AMOUNT
9804 API_MSG_TOO_SHORT Update firmware or replace PCB, check R-net configuration.
9805 API_MSG_TOO_LONG
9806 API_MSG_NOT_ENABLED Update firmware or replace PCB, check R-net configuration.
9807 API_RESPONDED_OUT_OF_TIME
9808 API_MSG_REQUIEREMENT_WRONG Update firmware or replace PCB, check R-net configuration.
9809 API_MSG_INVALID_IN_CURRENT_STATE
9810 DATA_PACKET_WITH_INVALID_SEQ_NR Update firmware or replace PCB, check R-net configuration.
9811 ACK_PACKET_WITH_INVALID_SEQ_NR
9812 INVALID_HEADER Update firmware or replace PCB, check R-net configuration.
9813 PACKET_TIMEOUT
9814 CHIP_INT_ERR0 Update firmware or replace PCB, check R-net configuration.
9815 CHIP_INT_ERR1
9816 HOST_RESTART_AFTER_CORRECT_INIT Update firmware or replace PCB, check R-net configuration.
9817 HOST_INCOMPATIBLE_SERIAL_PROTOCOL_VERSION
9820 CHIPSET_INTERNAL_QUEUE_OVERFLOW Update firmware or replace PCB, check R-net configuration.
9821 CHIPSET_HEARTBEAT