Fault log

Trouble:

The system maintains a fault log with counters. The fault log can be accessed via the Configurator Software (dealer level). To do that, please contact mo-vis for further instructions.

Fault Reason Required action
CPU error RAM CPU consistency check failed. Replace PCB.
CPU error FLASH CPU consistency check failed. Replace PCB.
CPU error STACK CPU consistency check failed. Replace PCB.
CPU error EEPROM CPU consistency check failed. Replace PCB.
Watchdog reset The watchdog kicked in. Update firmware or replace PCB.
Hard fault A hard fault in the CPU.
Unexpected case An invalid case occurred. Update firmware or replace PCB.
Null pointer An invalid pointer occurred.
Unexpected value Unknown command was received. Update firmware or replace PCB.
Out of bounds Access to an invalid memory location.
MSP slave Communication problem. Connection with the PC (Configurator Software) went wrong. Update firmware or update Configurator Software. Try again.
PCB test Factory test failed. A fault occurred during factory testing.
Assembly test Factory test failed A fault occurred during factory testing.
Field test Field test failed (calibration). A fault occurred during field testing (calibration).
Test flags One or more test flags not set. Redo tests and/or replace PCB.
Software wdt Software watchdog. Update firmware. Replace PCB.
Hall sensor left The left sensor is faulty. Replace sensor and calibrate.
Hall sensor right The right sensor is faulty.
Throttle left The left throttle is faulty. Replace throttle and calibrate.
Throttle right The right throttle is faulty.
R-net trip code There is an R-net trip code. Check R-net fault on joystick display or in the R-net PC Programmer.