Fault log
Trouble:
The system maintains a fault log with counters. The fault log can be accessed via the Configurator Software (dealer level). To do that, please contact mo-vis for further instructions.
Fault | Reason | Required action |
---|---|---|
CPU error RAM | CPU consistency check failed. | Replace PCB. |
CPU error FLASH | CPU consistency check failed. | Replace PCB. |
CPU error STACK | CPU consistency check failed. | Replace PCB. |
CPU error EEPROM | CPU consistency check failed. | Replace PCB. |
Watchdog reset | The watchdog kicked in. | Update firmware or replace PCB. |
Hard fault | A hard fault in the CPU. | |
Unexpected case | An invalid case occurred. | Update firmware or replace PCB. |
Null pointer | An invalid pointer occurred. | |
Unexpected value | Unknown command was received. | Update firmware or replace PCB. |
Out of bounds | Access to an invalid memory location. | |
MSP slave | Communication problem. | Connection with the PC (Configurator Software) went wrong. Update firmware or update Configurator Software. Try again. |
PCB test | Factory test failed. | A fault occurred during factory testing. |
Assembly test | Factory test failed | A fault occurred during factory testing. |
Field test | Field test failed (calibration). | A fault occurred during field testing (calibration). |
Test flags | One or more test flags not set. | Redo tests and/or replace PCB. |
Software wdt | Software watchdog. | Update firmware. Replace PCB. |
Hall sensor left | The left sensor is faulty. | Replace sensor and calibrate. |
Hall sensor right | The right sensor is faulty. | |
Throttle left | The left throttle is faulty. | Replace throttle and calibrate. |
Throttle right | The right throttle is faulty. | |
R-net trip code | There is an R-net trip code. | Check R-net fault on joystick display or in the R-net PC Programmer. |