Select Mode |
- |
- |
Select by click |
See below |
Start Scanning by Click |
Hold while Scanning |
Select Timed Click |
Continuous Scanning |
There are several possibilities to activate the outputs ( select modes):
- Select by click: in this mode, clicking shortly once or more times will activate the output (short close/open input). After the clicks are given:
- The output will be closed for a set time (depending on the output's Close Time setting) OR
- The selected output is locked until released (depending on the output's Lock setting
The period between the clicks needs to be shorter than the Action Delay.
- Start scanning by click: a short click will start the scanning of the active outputs. A corresponding number of beeps and a selection of LEDs indicate where the Multi Switch is in its scanning process.
When the desired output is selected, press again to activate it. The output will react:
- The output will be closed as long as the input is kept closed OR
- The output is locked until released (depending on the output's Lock setting
If you wait too long, the selection process will stop and no output will be activated. This is a built-in feature to cancel any unwanted input. The scanning of the outputs is done at an interval of Select/Scan Time.
- Hold while scanning: Keep the input closed and a scanning of the active outputs will start. A corresponding number of beeps and a selection of LEDs indicate where the Multi Switch is in its scanning process.
When the desired output is selected, release the input device. The output will react:
- The output will be closed for a set time (depending on the output's Close Time) OR
- The output is locked until released (depending on the output's Lock setting)
If you wait too long, the selection process will stop and no output will be activated. This is a built-in feature to cancel any unwanted input. The scanning of the outputs is done at an interval of Select/Scan Time.
- Select Timed Click: In this mode, the selected output depends on the duration and/or number of clicks.
- To operate output 1 to 3: keep the input closed and the Multi Switch will start to scan the first 3 active outputs. A number of beeps will be generated. The corresponding LEDs will also be activated.
- Short press (< Select/Scan Time): output 1
- Medium press (> Select/Scan Time, but < than 2x Select/Scan Time): output 2
- Long press (> 2x Select/Scan Time): output 3
- To operate output 4: execute a double click within the Select/Scan Time.
When the desired output is selected, release the input to activate it. The output will react:
- The output will be closed for a set time (depending on the output's Close Time setting) OR
- The selected output is locked until released (depending on the output's Lock setting)
If you wait too long, the selection process will stop and no output will be activated. This is a built-in feature to cancel any unwanted input.
- Continuous Scanning: In this mode, the active outputs are scanned all the time (continuously).
When the desired output is selected, close the input to activate it. The output will react:
- The output will be closed as long as the input is kept closed OR
- The output is locked until released (depending on the output's Lock setting)
|
Active outputs |
1 |
4 |
1 |
Number of outputs used. If set to '1', the switch will never enter Select Mode. |
Calibration Method (proximity mode only) |
- |
- |
Auto |
Note: Only useful in combination with a proximity sensor. See below |
Manual |
When your input is a proximity sensor, the Calibration Mode is useful:
- Auto: The Multi Switch will automatically calibrate over time. This is only useful when the user of the device is able to keep a distance of at least 30 mm from the sensor when not operated.
- Manual: The use of manual calibration is necessary when the activating part of the body remains constantly close to the sensor (less than 30 mm distance). If is therefore appropriate to calibrate manually at regular intervals (every day or after a few days).
Ask the user to go to the position where he would like the input to be open. Then press the button on the box and the system will store that position as the open reference. When the calibration is successful, a continuous beep will sound. If it was unsuccessful or if calibration mode is set to auto or a mechanical switch connected, a number of short beeps will be produced.
|
Sensitivity (proximity mode only) |
10 |
100 |
50 |
Note: Only useful in combination with a proximity sensor. Sensitivity of the proximity sensors. The higher the value, the more sensitive the device becomes. Reduce this value in case of false contacts. |
Output sequence |
- |
- |
Tip-Tip |
The Select Sequence is: |
Tip-Ring |
The Select Sequence is: |
Action Delay |
10 |
2500 |
50 |
In mS |
Select/Scan Time |
100 |
5000 |
1000 |
In mS |
Input beep |
- |
- |
None |
No sound (default) |
A short beep |
Select beep |
- |
- |
None |
No sound |
Medium |
A normal (medium) beep (default) |
Long |
A long beep |
Output beep |
- |
- |
None |
No sound |
Short |
A short beep (default) |
Medium |
A normal (medium) beep |
Quit beep |
- |
- |
None |
No sound |
Medium |
A normal (medium) beep |
Long |
A long beep (default) |