Curtiss-Wright R-net parameters
For more information, please refer to the Curtiss-Wright manual SK77981-14 | R-net Technical Manual | Chapter 7 - Controls.
External Profile Jack Detect
Value | Description |
---|---|
Off | The Twister Pro will function as a normally open switch. |
On | The Twister Pro will be able to detect both open- and short-circuits in the wiring. If such conditions are detected, the function associated with the External Profile Switch Jack will be disabled and a warning will be displayed on the screen. |
Note: should be set to No for the button to be able to detect open- and short circuits.
External On/Off Jack Detect
Value | Description |
---|---|
Off | The Twister Pro will function as a normally open switch. |
On | The Twister Pro will be able to detect both open- and short-circuits in the switch itself or its wiring. If such conditions are detected, a trip will occur. |
Limp | The Twister Pro will be able to detect both open- and short-circuits in the switch itself or its wiring. If such conditions are detected, the system will still allow Drive but at a reduced speed and will issue a visual and auditive warning. |