Parameter settings
| Setting | Description | Parameters | |
|---|---|---|---|
| Auto off | The device will automatically switch off after a set time (in minutes). Note: Changing the level will reset the timer. Note: A value of 0 means that the device will never switch off. |
240 | Default |
| 0 | Min. | ||
| 600 | Max. | ||
| 1 | Step | ||
| Levels | The number of available power levels. Note: If there are 3 levels, then the device will use the average value of the minimum and maximum temperature and fan speed for the 2nd level (see below). Note: If there is only 1 level, then the device will use the lowest temperature and fan speed (see below). |
3 | Default |
| 1 | Min. | ||
| 3 | Max. | ||
| Minimum temperature | The temperature (in °C) of the heater at the lowest power level. | 50 | Default |
| 40 | Min. | ||
| 80 | Max. | ||
| 5 | Step | ||
| Maximum temperature | The temperature (in °C) of the heater at the highest power level. | 75 | Default |
| 40 | Min. | ||
| 80 | Max. | ||
| 5 | Step | ||
| Minimum fan speed | The fan speed (airflow) (in %) at the lowest power level. | 20 | Default |
| 10 | Min. | ||
| 100 | Max. | ||
| 5 | Step | ||
| Maximum fan speed | The fan speed (airflow) (in %) at the highest power level. | 85 | Default |
| 10 | Min. | ||
| 100 | Max. | ||
| 5 | Step | ||