Error codes

Trouble: When a fault occurs, the LED of the Scoot Control will start to flash. A long delay is followed by a number of flashes with a short delay. Count the number of flashes and look in the table below.
Flash count Reason Required action
1 - -
2 Hall sensor left Replace sensor board and calibrate.
3 Hall sensor right
4 Throttle left Replace throttle sensor and calibrate.
5 Throttle right
6 Test flag failed Redo diagnostic tests.
7 CPU fault Replace PCB.
8 Code fault Update firmware. Replace PCB.
9 Software watchdog
10
  • P015-61: R-net failure
  • P015-71: LiNX failure
  • Check R-net configuration. Check fault log in the R-net PC programmer.
  • Check LiNX configuration.
11 Diagnostic test Test failed, redo test.
12 EEPROM fault Replace PCB
13 ADC driver fault Replace PCB
14 PWM X driver fault Replace PCB
15 PMW Y driver fault Replace PCB
16 IO expander fault Replace PCB
Note: 12-16 are only applicable for P015-71 Scoot Control LiNX.